Services
- Electrical and mechanical tests under defined conditions
- Walk-in temperature test chamber with reduced circulation air under steady state conditions
- Functional tests (e.g. temperature compensation), heat rise, derating
- Climate / climatic storage
Low temperatures |
up to -70 °C |
Dry heat |
up to 250 °C |
Damp heat (constant and variable climate) |
10...95 °C 10...95 % rel. humidity |
- Vibration test (sinusoidal)
Frequency |
up to 3000 Hz |
Acceleration |
up to 100 m/s² |
Deflection |
max. ±10 mm |
Test load |
max. 40 kg |
- Shock / continuous shock (halfsine)
Acceleration |
up to 300 m/s² |
Shock time |
max. 20 ms |
Test load |
max. 40 kg |